Abstract

This paper deals with Automatic generation control (AGC) of interconnected hydrothermal system in continuous-discrete mode using proportional-integral (PI) controller with different tuning approaches. Here the PI controller is initially tuned using local optimization technique such as Fminsearch (Existing MATLAB function) and optimal control strategies were taken as integral square error (ISE), integral time-absolute error (IATE) and integral time square error (ISTE). Then the same PI controller is tuned by using evolutionary algorithm i.e. Genetic Algorithm (GA). For the given system appropriate generation rate constraint (GRC) has been considered both for the thermal and hydro plants. System performances are examined considering 1 % Step Load Perturbation (SLP) in both thermal and hydro area with 1 second sampling period. Finally the performance of both the local and global optimization algorithms is compared in terms of the time domain specifi cations both for frequency deviation in each area, and tie line power.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.