Abstract

To compare peel-induced maculopathy (PIM) using surgical forceps versus the microvacuum pick (MVP). Consecutive eyes undergoing internal limiting membrane (ILM) peeling using either the MVP or forceps were assessed. En face optical coherence tomography (OCT) images at the level of the nerve fiber layer were generated for 6-month postoperative visit. The percentage of the imaged area showing PIM was termed the PIM index. PIM severity was additionally measured using a qualitative PIM severity scale. Seventy-four consecutive eyes underwent ILM peeling with either the MVP (36/74; 49%) or forceps (38/74; 51%). At month-6 postoperatively, the mean PIM index for forceps was 7.7% vs 4.7% for the MVP (P < 0.001, R2 = 0.15). At 6 months, 26/38 eyes (68.5%) in the forceps group had either moderate or severe PIM compared to 12/36 eyes (33.3%) in the MVP group (P = 0.001). ILM peeling with the MVP resulted in lower PIM severity compared to forceps. [Ophthalmic Surg Lasers Imaging Retina 2023;54:37-42.].

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.