Abstract

BackgroundLeg length discrepancy (LLD) after total hip arthroplasty (THA) is a known source of complications and a leading cause of litigation (J Bone Joint Surg Br 87:155–157, 2005). There are limited studies investigating surgical approach combined with the use of fluoroscopy intraoperatively and their potential effects on LLD after THA. The purpose of this study was to compare the direct anterior (DA) approach utilizing a fluoroscopic overlay technique and anterolateral (AL) approach and their potential effect on LLD.MethodsWe retrospectively reviewed 121 patients who had undergone primary THA from September 1, 2016 to November 1, 2018 by either DA or AL approach by two separate surgeons. Leg length discrepancies were measured on pre-operative post-anesthesia care unit (PACU) and on post-operative low anterior/posterior (AP) pelvis plain radiographs by two investigators blinded to each other’s measurements. To confirm inter-observer and intra-observer reliability between LLD measurements amongst investigators, a Pearson correlation test was performed. The primary outcome measurement was leg length discrepancy (LLD).ResultsWe observed LLD > 1.0 cm and LLD > 1.5 cm in the DA and AL groups. The DA approach group showed a mean LLD of 4.5 mm against 7.76 mm in the AL group (p < 0.00001). There was a significantly higher rate of LLD in the AL group as compared to the DA group (LLD> 1 cm (28% vs. 8%, p = 0.0037) and LLD > 1.5 cm (7% vs. 0%, p = 0.0096). The LLD measurements showed strong correlation in terms of inter-observer (r = 0.95) and intra-observer reliability (r = 0.99) between the two investigators (p < 0.001).ConclusionIn our patient cohort, the DA approach with fluoroscopic overlay technique had less LLD in comparison with the AL approach, suggesting that intraoperative fluoroscopic use does have an impact on LLD.

Highlights

  • Total hip arthroplasty (THA) is a successful and reliable procedure for pain relief as a treatment for advanced arthritis [1]

  • In our patient cohort, the direct anterior (DA) approach had less average Leg length discrepancy (LLD) in comparison with the AL approach, suggesting that surgical approach with use of fluoroscopy does have an impact on LLD

  • An explanation for the better accuracy of the DA group could be attributed to the intraoperative imaging that allows for immediate feedback to the surgeon

Read more

Summary

Introduction

Total hip arthroplasty (THA) is a successful and reliable procedure for pain relief as a treatment for advanced arthritis [1]. Leg length discrepancy is one of the top reasons for litigation following THA [3]. Leg length discrepancy (LLD) after total hip arthroplasty (THA) is a known source of complications and a leading cause of litigation (J Bone Joint Surg Br 87:155–157, 2005). There are limited studies investigating surgical approach combined with the use of fluoroscopy intraoperatively and their potential effects on LLD after THA. The purpose of this study was to compare the direct anterior (DA) approach utilizing a fluoroscopic overlay technique and anterolateral (AL) approach and their potential effect on LLD

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call