Abstract
Auroral luminosities at vacuum ultraviolet (VUV) wavelengths are combined with simultaneous and coincident ionospheric electron density measurements made by the Chatanika radar to relate ionospheric conductances to optical emissions. The auroral luminosities are obtained along the magnetic meridian through Chatanika with the auroral imaging photometers on the Dynamics Explorer 1 (DE 1) satellite as the radar scans in the magnetic meridian to measure electron density and conductivity as a function of altitude and latitude. The observations are used to determine an empirical relationship between the luminosities measured at VUV wavelengths and the Hall and Pedersen conductances. Of particular interest is the response of the photometer when using the VUV filter designated 123W. This filter admits the 130.4‐ and 135.6‐nm emissions of atomic oxygen and the Lyman‐Birge‐Hopfield (LBH) bands of N2. Model calculations of the LBH and O I (135.6 nm) contributions to the total measured luminosity indicate that the relation between 123W luminosity and Pedersen conductance is less sensitive to the average energy of the precipitating electrons than the corresponding relation between the Hall conductance and 123W luminosity. This is because both the luminosity and Pedersen conductance decrease with increasing electron energy. The luminosity decreases with increasing energy because the emissions are more strongly absorbed by O2 above the region of production. The Pedersen conductance decreases with increasing energy because the Pedersen mobility maximizes at an altitude of about 140 km. In contrast, the Hall conductance increases with increasing electron energy, so that the relation between Hall conductance and luminosity depends on the hardness of the precipitation. These qualitative results are confirmed using the simultaneously and coincidentally obtained measurements of conductance and 123W luminosity. The absolute difference between the model calculations and the experimental results indicates that the 130.4‐nm emissions account for 50–65% of the total photometer response with the 123W filter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.