Abstract

An experimental energy storage system has been designed using a horizontal concentric tube heat exchanger incorporating a medium temperature phase change material (PCM) Erythritol, with a melting point of 117.7 °C. Three experimental configurations, a control system with no heat transfer enhancement and systems augmented with circular and longitudinal fins have been studied. The results presented compare the system heat transfer characteristics using isotherm plots and temperature–time curves. The system with longitudinal fins gave the best performance with increased thermal response during charging and reduced subcooling in the melt during discharging. The experimentally measured data for the control, circular finned and longitudinal finned systems have been shown to vindicate the assumption of axissymmetry (direction parallel to the heat transfer fluid flow) using temperature gradients in the axial, radial and angular directions in the double pipe PCM system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.