Abstract

Seven water treatment works were selected to compare disinfection by-products (DBPs) formed when using chlorination and chloramination. DBPs measured included trihalomethanes (THMs), haloacetic acids (HAAs), haloacetonitriles (HANs), trihalonitromethane, iodinated THMs and nitrosamines. Generally treatment works that used chloramination were able to meet the European THM regulatory limit of 100 μg L −1 whereas the chlorinated works found it significantly more difficult. There were no significant differences in the levels of nitrogenous DBPs between the treatment works using chlorination or chloramination with the exception of the nitrosamine N-nitrosodimethylamine (NDMA) which was present at one treatment works in one season.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.