Abstract
Although digital radiographs and cephalometric analysis software are becoming increasingly popular in orthodontic offices, there is little information concerning their reliability of measurement of soft tissue or concerning comparison with conventional techniques. Our study shows good reliability of each imaging system (conventional and storage phosphor digital) and cephalometric analysis modality (manual tracing, Dolphin Imaging v. 7.0 and Vistadent Image Management system v. 8.0) with no statistical differences in reliability among the modalities. In the second part of our research comparing the means of the modalities using different subjects, there was no difference in mean Dolphin scanned values when compared with manual traced values whereas the other imaging modalities (Dolphin digital, Vistadent scanned, and Vistadent digital) were significantly different from the manual traced values. Dolphin digital was significantly different from Vistadent scanned and Vistadent digital, although there were no differences between Vistadent scanned and digital. In general, except for facial angle, these differences in modalities do not appear to be clinically significant. Although digital radiographs and cephalometric analysis software are becoming increasingly popular in orthodontic offices, there is little information concerning their reliability of measurement of soft tissue or concerning comparison with conventional techniques. Our study shows good reliability of each imaging system (conventional and storage phosphor digital) and cephalometric analysis modality (manual tracing, Dolphin Imaging v. 7.0 and Vistadent Image Management system v. 8.0) with no statistical differences in reliability among the modalities. In the second part of our research comparing the means of the modalities using different subjects, there was no difference in mean Dolphin scanned values when compared with manual traced values whereas the other imaging modalities (Dolphin digital, Vistadent scanned, and Vistadent digital) were significantly different from the manual traced values. Dolphin digital was significantly different from Vistadent scanned and Vistadent digital, although there were no differences between Vistadent scanned and digital. In general, except for facial angle, these differences in modalities do not appear to be clinically significant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.