Abstract

Difficult airway management in children is challenging. One alternative device to the gold standard of direct laryngoscopy is the STORZ Bonfils fiberscope (Karl Storz Endoscopy, Tuttlingen, Germany), a rigid fiberoptic stylette-like scope with a curved tip. Although results in adults have been encouraging, reports regarding its use in children have been conflicting. We compared the effectiveness of a standard laryngoscope to the Bonfils fiberscope in a simulated difficult infant airway. Ten pediatric anesthesiologists were recruited for this study and asked to perform three sets of tasks. For the first task, each participant intubated an unaltered manikin (SimBaby (TM), Laerdal, Puchheim, Germany) five times using a styletted 3.5 endotracheal tube (ETT) and a Miller 1 blade (group DL-Normal). For the second task, a difficult airway configuration simulating a Cormack-Lehane grade 3B view was created by fixing a Miller-1 blade into position in the manikin using a laboratory stand. Each participant then intubated the manikin five times with a styletted 3.5 ETT using conventional technique but without touching the laryngoscope (group DL-Difficult). In the third task, the manikin was kept in the same difficult airway configuration, and each participant intubated the manikin five times using a 3.5-mm ETT mounted on the Bonfils fiberscope as an adjunct to direct laryngoscopy with the Miller-1 blade (group BF-Difficult). Primary outcomes were time to intubate and success rate. A total of 150 intubations were performed. Correct ETT placement was achieved in 100% of attempts in group DL-Normal, 90% of attempts in group DL-Difficult and 98% of attempts in BF-Difficult. Time to intubate averaged 14 s (interquartile range 12-16) in group DL-Normal; 12 s (10-15) in group DL-Difficult; and 11 s (10-18) in group BF-Difficult. The percentage of glottic opening seen (POGO score) was 70% (70-80) in group DL-Normal; 0% (0-0) in group DL-Difficult; and 100% (100-100) in group BF-Difficult. The Bonfils fiberscope-assisted laryngoscopy was easier to use and provided a better view of the larynx than simple direct laryngoscopy in the simulated difficult pediatric airway, but intubation success rate and time to intubate were not improved. Further studies of the Bonfils fibrescope as a pediatric airway adjunct are needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.