Abstract

Mass transport in pulsating flow devices using either moving boundaries or oscillating imposed pressure drops are compared with each other by means of a calculation using a simple model. We conclude that there is no difference between the two configurations as long as one is interested only in the power required to move the fluid for the convective mass transport achieved. However, the boundary driven configuration is more efficient if the power is divided by the total mass transport where both the diffusive and convective parts are taken into account, the boundary driven configuration is more efficient. The amplitude of the piston stroke in the pressure driven configuration and the amplitude in the boundary driven case are assumed to be the same, and the inertia of the moving devices themselves are ignored in this calculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.