Abstract

A charge-coupled device camera was used for the optical monitoring of activated sludge flocs and filaments, and the image analysis results were compared with the effluent clarity at a full-scale activated sludge plant during a three-month period. The study included a maintenance stoppage at the wastewater treatment plant, which was followed by a settling problem. Thus, the study presents the development of floc morphology from poor flocculation to good flocculation. In this case, the evolution of flocs was a slow process, and the optimum floc morphology was achieved before the purification results improved. To diagnose the cause of the settling problems using optical monitoring, four major factors were found to be relevant: the mean area of the flocs, the amount of small particles, the amount of filament and the shape parameters of the flocs. In this case, the settling problem was caused by dispersed growth based on the image analysis results. In conclusion, the method used has the potential for usefulness in the development of monitoring applications to predict plant performance and also to diagnose the causes of the settling problems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.