Abstract

A detailed analysis of the accuracy in complex-reflection coefficient measurement by the six-port technique is discussed. The expression of the relative error in amplitude measurement of the complex reflection due to power-reading errors are derived in worst-case situation using both the basic six-port and sensitivity analysis theories. The precision of measurement of any point in the Smith chart is obtained by reference to lines of constant errors (amplitude and phase) drawn on the Smith chart for various proposed six-port correlators (junctions). A comparison of three proposed six-port designs shows that the Engens six-port design presents the best performance for a given power measurement accuracy. A maximum dynamic range of 60 dB seems to be a limit for six-port reflectometers using a good-quality power detector ( alpha =0.1%). >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.