Abstract

The clinical diagnosis of dry-eye is confirmed by a suitable test of tear production and the technique commonly used today to diagnose dry eye is the Schirmer's test (ST). Although the ST is easy to perform it gives variable results, poor reproducibility and low sensitivity for detecting dry eyes. Another test, the tear break up time (TBUT) is used to assess the stability of tears which if abnormal may also cause symptomatic dry-eye. We present the results of both these tests and a new test, which shows greater sensitivity than the ST in detecting aqueous tear deficiency. The fluorescein meniscus time (FMT) is a new test developed in conjunction with one of the authors (CL) and the Department of Ophthalmology at the University Hospital of Wales. The FMT is a measure of the rate at which a fluorescent tear meniscus is formed using 2% sodium fluorescein, a stopwatch and suitable illumination with a slit lamp. An open controlled study in 62 patients and 51 controls was conducted to compare the ability of ST, FMT and TBUT to detect dry-eye in a group of patients diagnosed with rheumatoid arthritis and symptomatic dry eyes for a minimum period of 6 months. A separate control group of 15 subjects was tested on three separate occasions to assess the reproducibility of the FMT test. All three tests showed a statistically significant difference between the patient and control populations; Mann-Whitney P < 0.001. There was a correlation between the right and left eye for all three tests in the control group (ST r(2) = 0.77, FMT r(2) = 0.98, TBUT r(2) = 0.94). This correlation was markedly reduced for FMT and TBUT in the patient population and was in keeping with the symptoms reported as being worse on one side in a proportion of the patients (FMT r(2) = 0.52, TBUT r(2) = 0.54, ST r(2) = 0.75). A correlation with age was also observed for all the three tests in the control group (ST r(2) = 0.74, FMT r(2)= 0.92, TBUT r(2) = 0.51), but not in the patient population (ST r(2) = 0.06, FMT r(2) = 0.18, TBUT r(2) = 0.03). A significant correlation was observed between the ST and FMT in both the control (ST vs FMT r(2) = 0.65) and patient population (ST vs FMT r(2) = 0.44). There was no value greater than 200 seconds for FMT recorded in the control group. Using this value to define an abnormal FMT, 85% of the patients (72% of the eyes tested) had an abnormal result. This was in contrast to 35% of patients (26% of the eyes tested) with abnormal results detected by ST. Using ANOVA and Student's paired t-test, there were no significant differences between the three sets of values recorded serially over 3 months to assess the reproducibility of the FMT. The average standard error of the mean was 2.72% and the average co-efficient of variation 4.07%. Our study suggests that the FMT is a more sensitive test with good reproducibility compared to the Schirmer's test. The FMT correlates with the ST and suggests that both tests measure aqueous tear deficiency. The FMT therefore is a better alternative to ST currently being used to test aqueous tear deficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.