Abstract

The effluents that are generated through Tanning process have high load of COD, BOD, Sulphides and Odour. Oxidation through aeration has been used for removing sulphide and COD in the tannery effluent. In the present study a comparison of normal aeration and oxygen injection in the presence and absence of catalyst MnSO4 were carried out. The three test setup were performed side by side and endured for a fixed duration till there was no further reduction observed in COD and Sulphide. Results showed that the maximum COD and Sulphide removal efficiencies in case of oxygen injection @ 0.5 LPM and addition of MnSO4 catalyst (5% of sulphide concentration) at pH 8.5. The removal of sulphide and COD through pure oxygen injection was found to be two times more effective than normal aeration. The removal efficiency of COD and Sulphide after 7 hours of oxygen injection @ 0.5 LPM with addition of catalyst MnSO4 was 82.68% and 76.83% respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.