Abstract
Particle Imaging Velocimetry (PIV) and Laser Doppler Velocimetry (LDV) measurements on a self-induced sloshing flow in a rectangular tank had been conducted in the present study. The PIV measurement result was compared with LDV measurement result quantitatively in order to evaluate the accuracy level of the PIV measurement. The comparison results show that the PIV and LDV measurement results agree with each other well in general for both mean velocity and fluctuations of the velocity components. The average disagreement level of the mean velocity between PIV and LDV measurement results was found to be within 3% of the target velocity for the PIV system parameter selection. Bigger disagreements between the PIV and LDV measurement results were found to concentrate at high shear regions. The spatial resolution and temporal resolution differences of the PIV and LDV measurements and the limited frames of the PIV instantaneous results were suggested to be the main reasons for the disagreement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.