Abstract

This paper compares the use of different lasers for the removal of Chlorinated Rubber (CR) coatings from concrete surfaces. The work involves the investigation of basic phenomena and reactions of CR to various laser wavelengths, including CO 2 (10.6 μm), diode (810 nm) and ArF excimer (193 nm) laser radiation. Characteristics of beam absorption, residues and the thermal effects on the materials are analysed by optical microscopy, SEM and EDX. By calculating the thermal loading ( γ) of the materials for the different lasers it has been revealed that the diode and excimer laser removal processes have very similar thermal loading with a γ value of 1.2 kJ/cm 3 for the excimer laser and 1.5 kJ/cm 3 for the diode laser. The similarity of the two arises from the fact that this thermal loading is of the same order of magnitude as the dissociation energy of the primary bonds. The thermal loading for the CO 2 laser process is around 100 J/cm 3, an order of magnitude smaller than the other two systems

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.