Abstract
We present a comparative study of the collinear and orthogonal pre-ablation dual pulse configurations of laser induced breakdown spectroscopy (LIBS) of silver using Nd:YAG lasers. The effect of the inter-pulse delay and the ratio of the laser pulse energies on the signal intensity enhancement for both the dual pulse configurations have been investigated. Using the first laser at 532 nm and second laser at 1064 nm delayed by 5 μs, we achieved nearly 2 times signal enhancement in the collinear double-pulsed configuration and nearly 12 times in the pre-ablation orthogonal configuration as compared to SP LIBS. It is ascertained that at the optimized value of the inter-pulse delay between the two lasers, the intensity ratio of the neutral silver lines follows the local thermo dynamical equilibrium (LTE) condition and it is also in excellent agreement with that of the relative transitions probabilities ratio listed in the NIST data base.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.