Abstract
In this paper, two passive solutions for noise reduction of PWM-fed induction machines are compared: the use of LC filter connected between the PWM inverter and the machine, and a three-phase damper wound inside the machine and connected to three capacitors. Firstly, the principle, advantages and disadvantages of each solution are recalled. The equivalent electrical circuits used for the study are also explained. Then, the effectiveness of both solutions in terms of voltage harmonic reduction and harmonic flux density reduction is discussed. The weight and size criteria are also studied. Results are given for two different power ranges of induction machines: 4 kW and 55 kW, and for two different switching frequencies of the PWM inverter: 3 kHz and 8 kHz.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Applied Electromagnetics and Mechanics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.