Abstract

Regarding to their unique physical and mechanical features, glasses and glass–ceramics are suitable materials for shielding purposes. The present study evaluates the shielding properties of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass system using Monte Carlo GEANT4 and MCNPX codes for X-ray radiations with an energy range of 20 to 100 keV. MAC values of the Ta0, Ta1, Ta2, Ta2.5, and Ta3 samples of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass were computed using Phy-X/PSD, GEANT4, and MCNPX codes and compared. According to the results, the programs have good compatibility with each other. For instance, in the energy of 40 keV and for the Ta2 sample, GEANT4 and MCNP codes are 1.445765406 and 1.517801204 cm2/g, respectively, indicating 7.419529525 and 2.829628418% differences with 1.562 cm2/g obtained using the Phy-X/PSD software. According to recent estimations, the Ta3 sample of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass system can be selected as the best shield compared with the other samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call