Abstract

A comparative evaluation has been conducted using three leading advanced flotation technologies, which utilize different types of bubble-particle attachment environment. Based on a statistical evaluation of the test data the Packed-Column technology, which provides a near plug-flow flotation environment due to the presence of corrugated packing material in the cell, produced the best separation performance due to its ability to support an extremely deep froth zone. However, because of the absence of an air sparging system and the consequent larger bubbles, the froth carrying capacity was the mininum with the Packed-Column technology. On the other hand, the throughput capacity achieved by the Jameson Cell technology, which has a self air-inducing co-current system that provides an intimate bubble-particle attachment environment characterized by an extremely high air fraction and ultrafine bubbles, was found to be maximum. The Microcel ™ technology achieved its maximum carrying capacity while providing a high energy recovery with a reasonably low reagent consumption.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.