Abstract

A three group prospective randomized experimental design was conducted to identify differences in frequency and severity of nasal injuries when comparing various interfaces used during continuous positive airway pressure (CPAP) and identified risk factors associated with injury. Seventy-eight neonates <1500g were randomized into three groups: continuous nasal prongs; continuous nasal mask; or alternating mask/prongs. Repeated measures ANOVA with Bonferroni correction demonstrated that significantly less skin injury was detected in the rotation interface group when compared to both mask and prong groups. In the final stepwise regression model (F=11.51; R2=0.221; p=0.006) significant predictors of skin injury included number of days on nasal CPAP (p<0.001) and current mean post menstrual age (p=0. 006). Reduced nasal injury was demonstrated using rotating mask/prong nasal interfaces. Future best practices must include precise selection of device size, developmental and CPAP device positioning with focused skin assessment including rapid intervention for skin injury.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.