Metaphyseal-diaphyseal junction (MDJ) fractures of the distal humerus are problematic to reduce and more susceptible to post-operative complications. This biomechanical study was designed to compare Kirschner wires (KW), lateral external fixation, and elastic stable intramedullary nails (ESIN) in simulated transverse MDJ fractures of various heights. Sagittally oblique, transverse MDJ fractures were created in fourth-generation composite bone models at three levels: high, mid, and low fractures, respectively, and then fixed with either Kirschner wires, lateral external fixation(EF), or ESIN respectively and tested in extension, flexion, valgus, varus, internal, and external rotations. In the high fractures, ESIN had better overall stiffness than the other techniques. In the mid groups, threecrossed pinning (1-medial and 2-lateral pins) had the best overall stiffness, followed by twocrossed pinning (1-medial and 1-lateral pins). In the low fractures, threecrossed pinning was superior to all other techniques. Two crossed pinning and three-lateral pinning techniques yielded comparable stiffness in the low fracture model. From a biomechanical perspective, ESIN provides the best overall stability for fractures located in the upper region of the MDJ, while percutaneous pinning is superior in stabilizing fractures of the lower region. Two lateral and one medial pins make the most stable crossed pinning construct for these fractures.