Abstract

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC. The charge density and divergence of the beam at the sample are the most important factors determining the quality of the Bragg-diffraction image (BDI). By applying the Robust Conjugate Directional Search (RCDS) algorithm for online optimization of the quadrupoles, the transverse beam size can be kept constant down to 75 µm from 1 to 13 pC. The charge density is nearly two orders of magnitude higher than the previously achieved value using a conventional solenoid. Using the BDI method we were able to extract the divergence of the beam in real-time and apply it to the emittance measurement for the first time. Our results agree well with simulations and with the traditional quadrupole scan method. The real-time divergence measurement opens the possibility of online optimization of the beam divergence (<0.2 mrad) at the sample with the increased beam charge. This optimization is crucial for the future development of single-shot ultra-fast electron microscope (UEM). Finally, we demonstrated BDI with significant improvement, up to 3 times higher peak intensity and 2 times sharper Bragg-diffraction peaks at 13 pC. The charge is now limited by the laser power and increasing charge may improve the quality of BDI further. The capability we demonstrated here provides us with opportunities for new sciences using near-parallel, bright and ultrafast electron beams for single-shot imaging, to directly visualize the dynamics of defects and nanostructured materials, or even record molecular movie, which are impossible using present electron-beam technologies.

Highlights

  • An ultra-fast electron diffraction facility delivering up to 0.8·108 electrons (13 pC) in a single-shot mode with the electron energy of 3.3MeV and the temporal resolution of 100 fs to 1 ps[1,2,3,4,5,6,7,8] represents a unique opportunity of simultaneous high temporal and spatial resolution for studies of many processes in physics, chemistry and biology

  • Such a system based on quadrupole multiplets has been built as a part of the existing instrument for ultrafast electron diffraction (UED) experiments at Accelerator Test Facility II (ATF-II), Brookhaven National Laboratory (BNL)

  • After an electron bunch generated by a 100 fs UV laser pulse exits from the photocathode RF gun, it is focused by a tunable quadrupole lens system down to a small beam size or a small beam divergence, to probe the sample

Read more

Summary

Introduction

An ultra-fast electron diffraction facility delivering up to 0.8·108 electrons (13 pC) in a single-shot mode with the electron energy of 3.3MeV and the temporal resolution of 100 fs to 1 ps[1,2,3,4,5,6,7,8] represents a unique opportunity of simultaneous high temporal and spatial resolution for studies of many processes in physics, chemistry and biology. We report our proof-of-principle design and experimental commissioning of broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. Such a system based on quadrupole multiplets has been built as a part of the existing instrument for UED experiments at ATF-II, BNL. It has been successfully commissioned with the capability of generating 3.3 MeV electron bunches with 13 pC charge with the focused beam size 75 μm[1,2,3]. The real-time measurement of the beam divergence makes online optimization of the beam opening angle possible with different charges

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have