Abstract

The control performance of Hall sensor-based high-speed brushless dc (BLdc) motor drives depends heavily on the accuracy of Hall sensor signals. Due to the existence of Hall signal errors, the system may operate under unbalanced conditions that will lead to asymmetric currents and high-torque ripple. For high-speed BLdc drive, using voltage source inverter (VSI) with the pulsewidth modulation (PWM) technique will also lead to PWM update delay that causes inaccurate commutation. In this article, two Hall signal errors, i.e., misaligned and uneven Hall signal errors, are investigated and a Hall signal balancing strategy is developed to detect Hall signal errors and regenerate balanced Hall signals. A novel PWM generation scheme is then proposed to eliminate the PWM update delay when using traditional VSI. Both simulation and experiment results have verified the effectiveness of the proposed strategy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.