The authors have implemented a new commandable threshold PHA-accumulation unit for the MIMI/LEMMS particle detection instrument of the Cassini mission to Saturn. The implementation is based on two full custom VLS ASICs specifically designed, fabricated, and space qualified for this project. The present system overcomes common fine tuning pre-flight and in-flight calibration difficulties associated with conventional fixed threshold systems of past missions, while significantly reducing weight and power. A brief description of the design as well as experimental results are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.