Abstract
A multi-species/reacting combustion study was performed. The focus of the study was to quantify the effects of variation in air extraction and power rates on flame/outlet temperatures of a General Electric (GE), Frame 5 gas turbine. The environmental contamination level due to generation of carbon monoxide was also reported. GE, Frame 5 gas turbine has been widely used around the world for power generation, and as mechanical drives. The combustion products were examined throughout a range of air extraction rates, upon which it was determined that the combustion liners were susceptible to damage at air extraction rates above 10%, and the environmental contamination level due to carbon monoxide was increased. Furthermore, the gas flow exiting the combustion liner became non-homogeneous (i.e. a pocket of relatively hot gas formed in the middle of the flow path), which would cause damage to the downstream components. In conclusion, the short-term monetary gains from using compressed air from a gas turbine do not justify the costs of down time for repairs and the replacement of expensive hot-gas-path components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.