Abstract

This paper introduces a coefficient clustering analysis method to detect and quantitatively measure damage occurring in composite materials using pulsed thermographic inspection. This method is based on fitting a low order polynomial model for temperature decay curves, which (a) provides an enhanced visual confirmation and size measurement of the damage, (b) provides the reference point for sound material for further damage depth measurement, (c) and reduces the burden in computational time. The performance of the proposed method is evaluated through a practical case study with carbon fibre reinforced polymer (CFRP) laminates which were subjected to a drop impact test with varying energy levels. A novel method for reducing an entire thermogram sequence into a single image is introduced, which provides an enhanced visualisation of the damage area.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.