Abstract
A sandwich-type solid phase radioimmunoassay, FRC-RIA (Finnish Red Cross-RIA) for hepatitis B surface antigen (HBsAg) is described. Polystyrene test tubes coated with sheep anti-HBs gamma-globulin serve as the solid phase. The technique is specific and has a sensitivity of about 1 ng/ml for the subtypes ad and ay of HBsAg when corresponding subtype-specific antibodies are used as reagents. The total incubation time can be shortened from over 20 h to 3 h, with almost equal sensitivity, when the incubation temperature is raised from room temperature to 45 degrees C. The test is economical in reagents and is applicable to routine use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.