Abstract

Bioretention cells in the Toronto region are usually sized to accommodate runoff from the 90th percentile storm, which has a depth of about 25 mm. This research examines the water quality control performance and cost of bioretention cells sized to satisfy alternative design criteria ranging from 5 to 50 mm. The long-term average runoff-capture efficiencies provided by representative bioretention cells are determined, and their capital as well as operation and maintenance costs are estimated. Results indicate that the current design criterion of 25 mm is probably too high and not cost-efficient. In fact, above some threshold levels, little improvement in runoff-capture and pollutant removal performances may be achieved if the design criterion is increased further, but cost would still linearly increase. Presented here is a methodology that can be used to properly consider both the performance and cost of bioretention cells for establishing a more cost-efficient design criterion. It is shown that a more cost-efficient design criterion for Toronto could be lower than the current one, and significant cost savings can be realized if a lower design criterion is implemented. Some inappropriate ways of quantifying the effective volume of storage provided by bioretention cells are also identified in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.