Abstract

Background & Hypothesis: We hypothesize that whole-body PET imaging with 62Cu-ETS and readily implemented tracer kinetic models, can enable absolute quantification of regional perfusion (mL•min-1•g-1) in a fashion that is reproducible; readily standardized across institutions; and logistically suitable for clinical implementation. 
 Experimental Design: Thirty-five paired 62Cu-ETS and H215O studies were performed in six Göttingen minipigs to validate the use of image-derived input functions. H215O estimates of tissue perfusion served as a reference standard for comparison with 62Cu-ETS. To demonstrate quantitative whole-body perfusion imaging in humans, paired 62Cu-ETS and H215O studies were performed in 14 renal cell carcinoma patients both prior to and following sunitinib therapy. 
 Results: The pig studies showed a strong correlation between regional blood flow estimates made with 62Cu-ETS and H215O, using image-derived input functions with tracer kinetic model-based corrections for 62Cu-ETS decomposition in blood (slope=0.932, R2=0.746). High quality voxel-wise 62Cu-ETS perfusion and blood volume parametric images demonstrated a strong correlation with H215O across all tissues within the imaging field-of-view. Using a same-day test-retest design, which was then repeated across two weeks, the animal study demonstrated good test-retest variability (TRV) for 62Cu-ETS and H215O with TRV of 6.3% ± 5.40% and 5.0% ± 4.77%, respectively. These findings strongly support application of the modeling methods to the human data, which is currently in progress. 
 Conclusion & Potential Impact: Whole-body imaging to non-invasively quantify regional perfusion holds promising potential for clinical implementation, using 62Cu-ETS PET coupled with tracer kinetic models that rely solely on the acquired imaging data.

Highlights

  • Background & Hypothesis: We hypothesize that whole-body PET imaging with 62Cu-ETS and readily implemented tracer kinetic models, can enable absolute quantification of regional perfusion in a fashion that is reproducible; readily standardized across institutions; and logistically suitable for clinical implementation

  • The pig studies showed a strong correlation between regional blood flow estimates made with 62Cu-ETS and H215O, using image-derived input functions with tracer kinetic model-based corrections for 62Cu-ETS decomposition in blood

  • High quality voxel-wise 62Cu-ETS perfusion and blood volume parametric images demonstrated a strong correlation with H215O across all tissues within the imaging field-of-view

Read more

Summary

Introduction

Background & HypothesisWe hypothesize that whole-body PET imaging with 62Cu-ETS and readily implemented tracer kinetic models, can enable absolute quantification of regional perfusion (mLmin-1g-1) in a fashion that is reproducible; readily standardized across institutions; and logistically suitable for clinical implementation.Experimental Design: Thirty-five paired 62Cu-ETS and H215O studies were performed in six Göttingen minipigs to validate the use of image-derived input functions. Background & Hypothesis: We hypothesize that whole-body PET imaging with 62Cu-ETS and readily implemented tracer kinetic models, can enable absolute quantification of regional perfusion (mLmin-1g-1) in a fashion that is reproducible; readily standardized across institutions; and logistically suitable for clinical implementation.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.