Abstract

To investigate the clinical effect of setting proportional pressure support (PPS) parameters by target tidal volume (VT) method. The study was conducted retrospectively on acute exacerbation of chronic obstructive pulmonary disease (AECOPD) patients admitted to Tianjin Third Central Hospital from January 2016 to December 2020. According to the PPS parameter setting method, the patients were divided into the airway blocking group and target VT group. The baseline characteristics, initial setting values of flow assist (FA) and volume assist (VA), respiratory system parameters, and clinical outcomes were collected and compared between the two groups. Fifty-nine patients were enrolled, 29 patients in the airway blocking group, and 30 in the target VT group. There was no statistically significant difference in baseline characteristics, compliance, resistance, and initial settings of FA and VA between the two groups. Compared with the target VT group, the respiratory rate (RR), mean arterial pressure (MAP), VT, and arterial partial pressure of oxygen (PaO2) recorded 1 hour after the initial setting of the PPS parameters in the airway block method group were significantly reduced [RR (times/minute): 21.0 (18.5, 22.5) vs. 23.0 (21.0, 25.0), MAP (mmHg, 1 mmHg = 0.133 kPa): 84.0 (79.0, 90.5) vs. 90.0 (87.0, 96.2), VT (mL): 305.24±41.07 vs. 330.87±46.84, PaO2 (mmHg): 68.0 (66.0, 73.5) vs. 74.0 (69.8, 82.5), all P < 0.05], while arterial partial pressure of carbon dioxide (PaCO2) and oral closure pressure (P0.1) were both increased significantly [PaCO2 (mmHg): 41.0 (39.0, 46.0) vs. 37.5 (35.0, 42.2), P0.1 (cmH2O, 1 cmH2O = 0.098 kPa): 1.42±0.78 vs. 0.90±0.67, both P < 0.05]. Compared with airway blocking group, the duration of weaning, ICU stay, and hospital stay in the target VT group were significantly shorter [duration of weaning (hours): 42.0 (24.0, 70.5) vs. 64.0 (30.5, 97.5), ICU stay: 10.00±3.38 to 13.28±5.41, hospital stay (days): 12.07±3.40 vs. 15.41±5.60, all P < 0.05]. There was no statistically significant difference in the invasive mechanical ventilation time, weaning failure rate, ICU mortality and in-hospital mortality between the two groups. This study suggested that the target TV method has the advantages of practicality, safety, convenience, and rapid to set PPS parameters than the airway block method, which shortens the duration of weaning and ICU stay, and has a good clinical prospect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.