Abstract
A clean-up method using high performance liquid chromatography (HPLC) and liquid chromatography/mass spectrometry (LC/MS) was developed to pursue trace amounts of microcystins in lake water. The method consisted of the combined usage of octadecyl silanized (ODS) silica gel and silica gel cartridges. In the first clean-up process, the retention behavior of microcystin RR on ODS silica gel cartridge was carefully observed together with microcystin LR, and 10% water-methanol was chosen as the best solvent system to elute microcystins from the ODS silica gel cartridge. Because many impurities still remained in the desired fraction from the raw water even after the clean-up with ODS silica gel, an additional clean-up process was developed using various cartridges. As a result of extensive experiments, the second clean-up process using silica gel cartridge was established, and the impurities were effectively eliminated. The present method including a tandem cartridge system allowed a precise analysis of microcystins in water samples from three different lakes at a 0.02 ppb level.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.