Abstract

Dialysis access steal syndrome (DASS) is an uncommon but often debilitating complication of dialysis access formation. We present a technical description of a novel arteriovenous fistula (AVF) banding technique for the treatment of DASS and the results of a short case series. A polyethylene terephthalate carotid patch is shaped with a slit at 1 end and saw tooth edges (resulting in a "Christmas tree" shape) so as to provide a ratchet mechanism to progressively constrict the draining vein of the AVF. This is performed with finger perfusion pressure measures to allow optimal compromise between distal extremity and AVF perfusion. Data on 6 patients with brachiocephalic AVF treated with this technique are included in a case series. During the follow-up of mean of 14 months (range, 2-36 months), all AVFs remained patent and in active use for dialysis. No alternative access was required in the immediate post- or perioperative period. All patients had relief of rest pain or evidence of healing at the last follow-up. Christmas tree banding with finger pressure measurements can offer successful treatment for DASS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.