Abstract
The current waste policy in EU aims at reducing the amounts of sludges to be disposed in landfill, encouraging their energy reuse (e.g. energy source, fertilizers, etc.). In this perspective a reduction of potentially toxic elements (PTEs) and water is welcome, in view of a more sustainable reutilization of sludges, e.g. in agriculture. Aim of this work was to set up a chemical-physical procedure, named modified Fenton process (patent n° PC201208 of 22/03/2012), which was able to improve the reduction of some PTEs (Zn, Ni, Cu, Pb, Cd and Cr) and water in municipal sewage sludges from anaerobic digestion, better than a conventional Fenton process, avoiding significant decreases of total organic carbon (TOC).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.