Abstract

A computational fluid dynamics (CFD) program, Fluent V4, was used to predict natural ventilation rates and airflow patterns of a multi-span, sawtooth greenhouse for various roof and side vent openings and outside wind speeds. Predicted rates were found to be both well above and well below a standard volumetric air exchange rate of 1.0 A.C. min–1. The maximum and most acceptable ventilation rates were obtained with the combined use of a windward side vent and leeward roof vents on all multi-span sections. Ventilation rates ranged from 1.4 to 4.01 A.C. min–1 for the best two-span case and 0.14 to 2.0 A.C. min–1 for the similar four-span case for outside wind speeds of 0.5 and 2.0 m s–1, respectively. Predicted ventilation rates ranged from 0.17 to 0.7 A.C. min–1 when no side vent was used and the roof vents were fully open.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.