Abstract
CFD is applied to study the effects of geometric factors and particle concentration of double-storey advection sedimentation tank on hydraulic state and particle removal for low turbidity raw water. The results show that the width has a great influence on the particle concentration at the outlet. When the width is 5m, the effluent turbidity can basically meet the design. The impact of hydraulic load on the weir about 3L/s/m on the particle concentration at the outlet is small. When the water depth is shallow, the particle concentration at the outlet increases significantly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.