Abstract
Abstract A CdTe detector with a Gd converter has been developed and investigated as a neutron detector for neutron imaging. The fabricated Gd/CdTe detector with the 25 μm thick Gd was designed on the basis of simulation results of thermal neutron detection efficiency and spatial resolution. The energy resolution of the Gd/CdTe detector is less than 4 keV, which is enough to discriminate neutron capture gamma rays from background gamma emission. The Gd/CdTe detector shows the detection of neutron capture gamma ray emission in the 155 Gd(n, γ) 156 Gd, 157 Gd(n, γ) 158 Gd and 113 Cd(n, γ) 114 Cd reactions and characteristic X-ray emissions due to conversion-electrons generated inside the Gd film. The observed efficient thermal neutron detection with the Gd/CdTe detector shows its promise in neutron radiography application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.