Abstract
GE-7031 varnish, a commonly used low-temperature adhesive and electrical insulator owing to its high thermal conductivity and mechanical strength at low temperatures, was used as a sample matrix for low-temperature powder X-ray diffraction measurements of the negative thermal expansion (NTE) material ScF3. When ScF3powder was mixed with GE-7031 varnish, an unexpected cubic to rhombohedral phase transition in the ScF3sample was observed at ∼50 K, and it exhibited smaller low-temperature unit-cell volumes than samples without the varnish matrix. Experimental observations and quantitative estimates suggest that these anomalies are the result of stress induced by a thermal expansion mismatch between the varnish matrix (large positive coefficient of thermal expansion, CTE) and ScF3(quite large negative CTE). The use of GE-7031 varnish as a sample matrix for low-temperature measurements should be approached with caution if a large thermal expansion mismatch is expected.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.