Abstract

Port-site herniation (PSH) is a rare complication observed postlaparoscopic surgery, typically associated with port sizes of 10 mm or larger, commonly occurred at umbilicus. While occurrences of extra-umbilicus with port size smaller than 10 mm are rare, we present a case detailing a lateral 7 mm PSH diagnosed on the 8th day following a total laparoscopic hysterectomy. The patient exhibited clinical symptoms indicative of partial small bowel obstruction, which became apparent on the third postoperative day. Computed tomography revealed significant small bowel dilatation and herniation through the previously employed 7 mm trocar site. Notably, this trocar site had been utilized with uterine screw. Prompt laparoscopic repair successfully addressed the herniation. The patient demonstrated satisfactory recovery and was subsequently discharged. While current practice recommends fascial incision closure for port size ≥10 mm. In light of our case, we propose considering fascial closure for small-size trocar subjected to any use of a manipulator.