Abstract

Hemodynamic unloading by left ventricular assist devices (LVADs) in patients with advanced heart failure can result in reverse remodeling and cardiac recovery allowing pump removal. Ventriculoplasty during explantation may cause fibrosis and ventricular scars which can provide a substrate for reentry, a common cause of ventricular arrythmias. In this case report, we describe the clinical course of a patient who suffered a cardiac arrest in the following few months after undergoing LVAD explantation because of cardiac recovery. This case highlights a potential risk related to complete LVAD explantation with ventriculoplasty and patch repair of the apex.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.