Abstract

In this work, a higher-order Proton Exchange Membrane (PEM) Fuel Cell system is controlled using a cascaded control approach. The primary and secondary controllers, NPID/PI, are non-linear proportional-integral-derivative and proportional-integral, respectively. The suggested cascade approach controls the stack voltage by adjusting the air compressor voltage to maintain the oxygen excess ratio value within limits. Two additional cascade control structures, PID/PI and FOPID/FOPI (fractional order PID and fractional order PI), are also created for a fair comparison. A genetic algorithm is used to determine the controller's optimal parameters by minimising the time integral absolute error of the primary controller. Results show that NPID/PI control structure achieves the minimum value of settling time and overshot (0.9514 s, 0.021%) compared to FOPID/PI (1.8980 s, 0.036%) and PID/PI (3.2308 s, 0.092%), respectively. Finally, it can be concluded from the result of setpoint tracking, disturbance rejection, and noise suppression that the proposed controller is efficient and robust compared to other designed controllers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call