Abstract

A simple calibration technique is presented for the measurement of the reflection coefficients of an open-ended waveguide. The accuracy of this calibration can be improved by using a waveguide isolator or attenuator between the adapter and the directional coupler. This calibration technique can be further improved by using the time domain gating feature of a vector network analyzer. The admittance of the open-ended waveguide has been measured using this calibration technique at X band and Ku band. The measured results show good agreement with the calculated ones and with those measured using waveguide calibration kits or TRL calibration kits. The calibration technique can be extended to other frequency bands provided that waveguide directional couplers and isolators at those frequency bands are available. The calibration technique can be used for measurements of dielectric permittivity and permeability using an open-ended waveguide system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.