Abstract
A calibration method to calibrate both the camera intrinsic parameters and the structured light projector based on three collinear points with any known distance is presented. First, fix one point of the target and move it in the camera field of view with unknown viewpoint at least six times. Next, use camera to obtain the image of the points so as to identify the camera intrinsic parameters. Then, move the target in the structure light plane at least twice. Using the calibrated camera obtains the images of the three points and adopts the principle of triangulation to work out the coordinates of the calibration points in the camera coordinate system. Finally, employ the random sample consensus algorithm to eliminate the outlier and adopt the genetic algorithm for system identification to find the coefficients of the structured light plane. The average absolute error and the average relative error of the segment measurement with this structured light system are 0.13 mm and 0.04%, respectively. Those show t...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Computational Intelligence Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.