Abstract

In this paper, a calibration of six-port reflectometer using a new technique program is presented. It has been shown that a calibration procedure is based on explicit method, the method that capturing the output wave forms of six-port junction and determines the complex relationship between the two waves present at the input from the value of four outputs. The number of calibrating standards and the computation effort required are the most important parameters in selecting a calibration technique. Comparison between the results obtained from the new calibration method program with measurement results show the validity of the method proposed. This calibration technique can be used in general six-port direct digital receiver.

Highlights

  • A Calibrating Six-Port Compact Circuit using a New Technique ProgramDept. of physics, Lab CSEHF, Faculty of sciences of Tunis, El-manar, Tunisia Dept. of electronics, Riyadh College of Technology, tvtc, Saudi Arabia

  • Six-port concept has been successfully applied in modern communication receivers

  • Calibration procedure is very important for the measurement accuracy

Read more

Summary

A Calibrating Six-Port Compact Circuit using a New Technique Program

Dept. of physics, Lab CSEHF, Faculty of sciences of Tunis, El-manar, Tunisia Dept. of electronics, Riyadh College of Technology, tvtc, Saudi Arabia . Of physics, Lab CSEHF, Faculty of sciences of Tunis, El-manar, Tunisia Dept. Abstract—In this paper, a calibration of six-port reflectometer using a new technique program is presented. It has been shown that a calibration procedure is based on explicit method, the method that capturing the output wave forms of sixport junction and determines the complex relationship between the two waves present at the input from the value of four outputs. Comparison between the results obtained from the new calibration method program with measurement results show the validity of the method proposed. This calibration technique can be used in general six-port direct digital receiver

INTRODUCTION
SYSTEM DESIGN
The Proposed Six-Port Circuit
Reflectometer System with Proposed Six-Port
CALIBRATING TECHNIQUE PROPOSED
Validation by Measuring Test Loads
CONCLUSION
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.