Abstract

Beam power measurement usually adopts water flow calorimetry (WFC) for neutral beam injector. In this article a calculation model of beam power for EAST neutral beam injector was given basing on thermocouples installed in the calorimeter plate. In order to obtain calculation model: (1) the heat flux of the surface of beam stopping elements was calculated using heat transfer science, (2) the processing method of data obtained from the thermocouple was given, (3) mathematic derivations of beam power is given basing on theory of Gaussian distribution. The model could point another way to beam power measurement of EAST neutral beam injector besides WFC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.