Abstract

This study aimed to describe and assess the accuracy and feasibility of a novel technique for ultrasound-guided maxillary nerve block using the lateral pterygoid plate (LPP) approach via the pterygopalatine fossa (PPF) in a soft cadaveric model. Ten soft cadavers were studied. The curved array ultrasound transducer probe was applied over 1 side of the face of the cadavers in the open-mouth posture. It was placed transversely below the zygomatic arch for identifying the border of the maxillary tuberosity and the LPP. We tilted the curve probe from the caudal to the cranial direction until the uppermost part of the PPF was identified. The in-plane needle approach was used from the anterior-to-posterior and lateral-to-medial directions through the fossa, and 3 mL of methylene blue dye was injected. The spread of injectate after ultrasound-guided maxillary nerve block using the LPP approach was successfully performed in all cadavers as demonstrated by visualized moderate to marked traces of methylene blue within the PPF. No accidental injections in the maxillary arteries or facial nerves were observed. This cadaveric study suggests that ultrasound-guided maxillary nerve block using the LPP approach via the PPF has a high degree of accuracy and feasibility. Further studies are required to confirm its efficacy and safety for clinical application.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.