Abstract

Fast and accurate test Cr(VI) in the whole blood is particularly critical for the treatment and prevention of Cr(VI) poisoning. Here, a blood compatible, high-efficient sensor based on the magnetic glassy carbon electrode (MGCE) that modified by conductive polyaniline (PANI), heparin and tannin modified Fe3O4 nanoparticles (magnetic tannin-modified adsorbent, MTA) with high adsorption ability toward Cr(VI) ions was developed. Results indicated the designed PANI/Hep/MTA/MGCE exhibited high sensitivity for Cr(VI) in the concentration range of 10−7 to 10−4 ppm with a 0.87 μM detection limit (3σ method). In particular, this prepared sensor not only exhibited outstanding electrochemical performance for Cr(VI) detection, but also possessed good antibiofouling characteristics due to the existence of heparin, which can provide guarantee for direct detection of Cr(VI) in the whole blood.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.