Abstract

A biomechanical study was undertaken to evaluate the relative stability of three types of internal fixation used for ankle arthrodesis. Crossed screw fixation, RAF fibular strut fixation, and T-plate fixation were tested in 30 cadaver ankles using an MTS machine. T-plate fixation consistently provided the stiffest construct when compared with the other types of fixation. Failure occurred by distraction of bony surfaces, posterior to the plane of fixation, in the crossed screw and RAF groups. In contrast, failure in the T-plate group occurred through compression of bone anterior to the midcoronal plane of the tibia. Although the stability of fixation is only one factor in determining the success or failure of ankle arthrodesis, the results of this study would support T-plate fixation over the other forms tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.