Abstract

In situ physico-chemical disinfection of high risk faecal waste is both effective and widely used as a sanitation management strategy for infection prevention and control. Systematic tests where the performance of alternative physico-chemical disinfection methods is systematically compared and optimized must be based on reliable protocols. These protocol are currently not adequately addressing the neutralization related issues: the neutralization of the tested disinfectant after specified conditions of concentration and contact time (CT) is necessary to prevent continued disinfection after the intended contact time; moreover such neutralization is often necessary in practice and on a large scale to prevent adverse health and ecological impacts from remaining disinfectant after the target CT is achieved. Few studies adequately assess the extent of neutralization of the chemical disinfectant and are intended to optimize on-site disinfection practices for waste matrices posing high microbial risks. Hence, there is a need for effective and reproducible neutralization protocols in chemical disinfection trials and practice. Furthermore, for most of chemical disinfectants used in healthcare settings there is no practical methodology to reliably and conveniently measure the residual disinfectant concentration after its neutralization and also determine the optimum concentration of the neutralizer. Because some neutralizing compounds can themselves be toxic to the test microorganisms, it is necessary to optimize neutralization procedures in disinfection experiments for the development of infection control practices using accepted positive control microbes. In the presented work, a stepwise bioassay-based protocol using representative faecal indicator microbes is described for optimizing chemical disinfection and subsequent disinfectant neutralization of any infectious faecal waste matrix. The example described is for the quaternary ammonium compound benzalkonium chloride and its recommended chemical neutralizer in a high strength human faecal waste matrix.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.