Abstract

The paper deals with a brief presentation of a part of the performed experimental tests of the prefabricated reinforced concrete structural system 'AMONT' for construction of various types of modern industrial halls. The test results are analyzed for two industrial halls both constructed according to this structural system but in the different phases of construction, tested in the full scale by application of AMBIENT vibration method. From the obtained Fourier spectra for measured ambient vibrations in two orthogonal direction for the structure without walls and the other with fa?ade and filling walls, a significant discrepancy in their natural frequencies has been observed, and some conclusions about the influence of panel walls on dynamic characteristic the frame structure have been drawn out. The paper used some data of the research after the earthquake in Montenegro which took place on 15th of April 1979.