Abstract
Nuclear power plants and research facilities commonly employ the so-called scaling factor (SF) method to quantify the activity of difficult-to-measure (DTM) radionuclides within their radioactive waste packages. The method relies on the establishment of a relationship between an easy-to-measure (ETM) radionuclide, called key nuclide (KN), and difficult-to-measure radionuclides, after the collection of a representative sample from the waste population. The distribution of the scaling factors, as well as the parameters defining the distribution, can change over time. Therefore, the accuracy of the calculated activity of the DTM radionuclides depends on the capacity of the scaling factor method to follow the time evolution of the waste population. In practice, waste producers collect periodically new samples from the waste population and check the variation and the validity of the scaling factors. In this article, we present a simple Bayesian framework to update scaling factors when a new data set becomes available. The method is tested and validated for radioactive waste produced at CERN (European Organization for Nuclear Research) and can be easily implemented for waste of different origin.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.